PXI-6651

National Instruments

PXI-6651

National Instruments

Description

The PXI-6651 by National Instruments is a versatile Slave Synchronization Module designed for precise timing in PXI systems. With options for different part numbers and a wide frequency range for its CLKIN input, this reliable device allows users to synchronize their instruments and achieve accurate coordination.

The PXI-6651 is a model manufactured by National Instruments, a renowned company known for its high-quality electronic equipment. It has two part numbers, namely 778725-01 and 188268D-03, providing options for users to select the most suitable version. This device is specifically designed as a Slave Synchronization Module, providing synchronization capabilities in a PXI (PCI eXtensions for Instrumentation) system. It serves as an excellent tool for implementing precise and accurate timing across multiple instruments within a PXI system. One of the notable features of the PXI-6651 is its Reference Clock Input, which operates at a frequency of 10 MHz. This input allows the device to receive an external clock signal to synchronize its timing with other instruments or systems. By using this feature, users can ensure precise coordination between different modules within their PXI setup. Furthermore, the PXI-6651 offers a wide frequency range for its CLKIN input, spanning from 1 MHz to 105 MHz. This flexibility allows users to adapt the device to different project requirements and choose the appropriate frequency within this range. This feature ensures compatibility with various signal sources and supports a diverse range of applications. Overall, the PXI-6651 by National Instruments is a reliable and versatile Slave Synchronization Module, offering synchronization capabilities and compatibility with external clock signals of different frequencies. Its robust design and wide frequency range make it a valuable tool for precise timing and coordination in PXI systems.

Made By National Instruments
Model Number PXI-6651
Part Numbers 778725-01, 188268D-03
Type Slave Synchronization Module
Reference Clock Input 10 MHz
CLKIN Frequency Range 1 MHz to 105 MHz

Distribution Cache Shipping Info and Options

Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.

Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.

Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.

 

Shipping Options:

Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.

Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.

Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.

2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go

Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.

 

Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.

Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.

Question:

What is the PXI-6651?

Answer:

The PXI-6651 is a Slave Synchronization Module designed for synchronization in PXI systems, manufactured by National Instruments.

Question:

What company manufactures the PXI-6651?

Answer:

National Instruments manufactures the PXI-6651.

Question:

What are the part numbers for the PXI-6651?

Answer:

The PXI-6651 has two part numbers: 778725-01 and 188268D-03.

Question:

What is the purpose of the Reference Clock Input on the PXI-6651?

Answer:

The purpose of the Reference Clock Input on the PXI-6651 is to receive an external clock signal at a frequency of 10 MHz to synchronize its timing with other instruments or systems within a PXI setup.

Question:

What is the frequency range for the CLKIN input on the PXI-6651?

Answer:

The frequency range for the CLKIN input on the PXI-6651 spans from 1 MHz to 105 MHz, allowing users to adapt the device to different project requirements and ensure compatibility with various signal sources.