776571-02

National Instruments

776571-02

National Instruments

Description

Part number 776571-02, the National Instruments SCXI-1001 Chassis is a rugged and low-noise chassis designed to accommodate up to 12 SCXI modules. With 3 internal analog busses and 12 slots, this chassis can power SCXI modules and handle trigger, timing, and signal routing between modules and digitizers.

The SCXI-1001 Chassis by National Instruments, part number 776571-02, is a rugged and low-noise chassis designed to accommodate up to 12 SCXI modules. With 3 internal analog busses and 12 slots, this chassis can power SCXI modules and handle trigger, timing, and signal routing between modules and digitizers. It is compatible with major operating systems and driver software, making configuration and operation simple. The chassis offers seven different power options for different countries and can be reconfigured easily. It can be programmed using software packages such as LabVIEW or LabWindows/CVI, speeding up development time. The SCXI-1001 has optional rear or front rack mountable configurations and features a forced air cooling mechanism. This chassis can synchronize timing between the DAQ device and modules, allowing for scanning input channels from multiple modules at a high rate. Despite its obsolete status, the SCXI-1001 is still available for purchase and repairs from Apex Waves.

Made By National Instruments
Part Number 776571-02 SCXI-1001, 12-Slot Chassis
Voltage Compatibility Swiss 220 VAC
Internal Configuration 3 Internal Analog Busses and 12 slots
Country Compatibility Can be reconfigured for use in different countries
Cooling Mechanism Forced air cooling

Distribution Cache Shipping Info and Options

Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.

Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.

Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.

 

Shipping Options:

Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.

Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.

Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.

2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go

Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.

 

Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.

Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.

Question:

What is the purpose of the SCXI-1001 Chassis by National Instruments, part number 776571-02?

Answer:

The SCXI-1001 Chassis by National Instruments, part number 776571-02, is designed to house up to 12 SCXI modules, providing power and enabling trigger, timing, and signal routing between modules and digitizers.

Question:

How many SCXI modules can the SCXI-1001 Chassis accommodate?

Answer:

The SCXI-1001 Chassis can accommodate up to 12 SCXI modules.

Question:

What type of software can be used to program the SCXI-1001 Chassis?

Answer:

The SCXI-1001 Chassis can be programmed using software packages such as LabVIEW or LabWindows/CVI.

Question:

What cooling mechanism does the SCXI-1001 Chassis feature?

Answer:

The SCXI-1001 Chassis features a forced air cooling mechanism.

Question:

Can the SCXI-1001 Chassis still be purchased despite its obsolete status?

Answer:

Yes, the SCXI-1001 Chassis can still be purchased and repaired from Apex Waves despite its obsolete status.