The 777687-39 SCXI-1339 Terminal Block is designed for use with the SCXI-1129 Multiplexer Switch, simplifying wiring for analog signals with its 2-wire, dual 4 by 32 matrix configuration. Users can easily plug it into the front-end connector of the SCXI-1129 and securely hold it in place with thumbscrews, with a maximum working voltage of 150 V and surge voltage resistance up to 800 V.

777687-39 SCXI-1339 is a front-mounting Terminal Block designed specifically for use with the National Instruments SCXI-1129 Multiplexer Switch. This Terminal Block allows users to configure the SCXI-1129 as a 2-wire, dual 4 by 32 matrix, simplifying wiring for analog signals. It can be easily plugged into the front-end connector of the SCXI-1129 and held securely in place with thumbscrews. The maximum working voltage allowed is 150 V, with tested surge voltage resistance up to 800 V. The SCXI-1339 offers control of dual, independent 4 x 32 matrixes, with connections to rows made through the Terminal Block or the HVAB, and columns accessed via the Terminal Block. While the SCXI-1339 has been declared obsolete by National Instruments, it can still be purchased and repaired through Apex Waves. Installation and configuration of the Terminal Block require no additional software or hardware resources.

Made By National Instruments
Part Number 777687-39
Compatible Device SCXI-1129 Multiplexer Switch
Configuration 2-wire, dual 4x32 matrix
Working Voltage 150 V maximum channel-to-channel and channel-to-earth
Surge Voltage Capacity 800 V

Distribution Cache Shipping Info and Options

Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.

Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.

Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.

 

Shipping Options:

Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.

Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.

Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.

2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go

Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.

 

Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.

Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.

Question:

Which National Instruments product is the SCXI-1339 designed to be used with?

Answer:

The SCXI-1339 is designed specifically for use with the National Instruments SCXI-1129 Multiplexer Switch.

Question:

What configurations does the SCXI-1339 allow for the SCXI-1129?

Answer:

The SCXI-1339 allows users to configure the SCXI-1129 as a 2-wire, dual 4 by 32 matrix.

Question:

What is the maximum working voltage of the SCXI-1339?

Answer:

The maximum working voltage of the SCXI-1339 is 150 V.

Question:

How is the SCXI-1339 attached to the SCXI-1129?

Answer:

The SCXI-1339 can be easily plugged into the front-end connector of the SCXI-1129 and held securely in place with thumbscrews.

Question:

Despite being declared obsolete, where can one purchase or repair the SCXI-1339?

Answer:

Although obsolete, the SCXI-1339 can still be purchased and repaired through Apex Waves.