778572-75 NI PXI-2575 196 ch Multiplexer Switch Module by National Instruments is a versatile high-density PXI module designed for automated test applications. Featuring electromechanical relays for accurate signal routing, this module offers reliable operation with hardware triggers for improved test accuracy.

778572-75 NI PXI-2575 196 ch Multiplexer Switch Module is a high density PXI module designed by National Instruments for a wide range of channel automated test applications. This module features electromechanical relays for directing signals to measurement instruments or source units. It offers reliable and deterministic operation with hardware triggers to improve test accuracy. The PXI-2575 can be configured as a 1-wire 196 x 1 multiplexer, a 2-wire 95 x 1 multiplexer, or a 2-wire 98 x 1 multiplexer, making it versatile for different testing needs. The device has socketed relays for easy replacement and a long electrical life of approximately 105 operations. It also includes a relay count tracking feature for predictive maintenance and minimal system downtime. The PXI-2575 is not recommended for 2-wire resistance measurements, with a fast operating time of 1 ms and a maximum of 3.4 ms. It can be programmed using various software packages and drivers, including NI-SWITCH and NI-DAQmx, and is compatible with different cable types. With dimensions of 8.5 x 0.8 x 5.1 inches and a weight of 8.1 oz., this module is compact and portable for various testing environments.

Made By National Instruments
Part Number 778572-75
Multiplexer Configuration Options 1-wire 196 x 1, 2-wire 95 x 1, 2-wire 98 x 1
Signal Handling Maximum of 60 W, 62.5 VA (DC to 60 Hz) per channel, 20 MHz bandwidth
Relay Characteristics Electrical life of approximately 105 operations, typical operating time 1 ms, maximum operating time 3.4 ms
Physical Specifications 8.1 oz. weight, 8.5 x 0.8 x 5.1 in dimensions

Distribution Cache Shipping Info and Options

Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.

Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.

Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.

 

Shipping Options:

Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.

Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.

Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.

2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go

Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.

 

Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.

Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.

Question:

What is the purpose of the 778572-75 NI PXI-2575 196 ch Multiplexer Switch Module?

Answer:

The 778572-75 NI PXI-2575 196 ch Multiplexer Switch Module is designed for a wide range of channel automated test applications, where it directs signals to measurement instruments or source units using electromechanical relays.

Question:

In which configurations can the PXI-2575 be set up for testing?

Answer:

The PXI-2575 can be configured as a 1-wire 196 x 1 multiplexer, a 2-wire 95 x 1 multiplexer, or a 2-wire 98 x 1 multiplexer, offering versatility for different testing needs.

Question:

What features does the PXI-2575 offer to ensure reliability and maintenance efficiency?

Answer:

The PXI-2575 offers features like reliable and deterministic operation with hardware triggers, socketed relays for easy replacement, a long electrical life of approximately 10^5 operations, and a relay count tracking feature for predictive maintenance.

Question:

Is the PXI-2575 module recommended for 2-wire resistance measurements?

Answer:

No, the PXI-2575 module is not recommended for 2-wire resistance measurements.

Question:

What programming software and drivers are compatible with the PXI-2575, and what are its physical dimensions?

Answer:

The PXI-2575 can be programmed using NI-SWITCH and NI-DAQmx software packages and drivers. It has dimensions of 8.5 x 0.8 x 5.1 inches and a weight of 8.1 oz., making it compact and portable for various testing environments.