779176-03 PXI-5412 Waveform Generator, with 256 MB memory, offers enhanced signal quality through digital interpolation and analog filtering. This device provides excellent passband flatness and low-distortion output, compatible with NI-FGEN driver software for seamless integration into various application development environments.

779176-03 PXI-5412 PXI Waveform Generator, 20 MHz, 14 bits, 100 MS/s, 1 Channels, 256 MB National Instruments PXI-5412 Waveform Generator utilizes computerized interpolation to enhance the output signal nature of smooth waveforms. Each digital-to-analog converter produces reconstruction images in the recurrence domain because of the conversion process. This model comes in three configurations: the PXI-5412 with 8 MB memory (Part Number: 779176-01), the PXI-5412 with 32 MB memory (Part Number: 779176-02), and the PXI-5412 with 256 MB memory (Part Number: 779176-03). The device has a maximum bandwidth of 20 MHz, and has an update rate of up to 100 MS per second. By utilizing a high-order filter like low cutoff recurrence, the imperfections of the channel, including passband ripple and nonlinear phase, significantly influence generator execution. The National Instruments PXI-5412 Waveform Generator utilizes digital interpolation to build the successful testing rate, migrating the reconstruction images to higher frequencies. By doing so, the required simple channel cutoff recurrence is expanded, which decreases channel twisting impacts. With the mix of digital interpolation and analog filtering, the PXI-5412 Waveform Generator can have excellent passband flatness and improved image rejection, ensuring a low-distortion output signal. The device is run using the NI-FGEN driver software which is compatible with software packages/application development environments (ADEs) such as LabVIEW, LabWindows/CVI, or Measurement Studio. It has a recommended warm-up time of 15 minutes and should be externally calibrated at least once every 2 years. The National Instruments PXI-5412 can be customized to sequence and loop an arrangement of waveforms. It has a recommended operating temperature range of 0 °C to 55 °C, and a storage temperature range of -25 °C to 85 °C. PXI-5412 Mature Status has been announced by National Instruments, but the waveform generator will still be available for purchase and repairs by Apex Waves. The PXI-5412 is available to be calibrated. While the recommended calibration period for individual parts varies, most parts should be calibrated either annually or every two years to ensure accuracy. If you need the PXI-5412 calibrated, Apex Waves provides options. We offer high-quality NIST accredited calibrations through a 3rd party, with an average turnaround time of 1 to 2 weeks. When you order the PXI-5412 with us, you can request basic (unaccredited) in-house calibration that will calibrate the part to the manufacturer specifications prior to being shipped. Call or email us today for more information about calibrating the PXI-5412!

Made By National Instruments
Part Number 779176-03
Frequency Bandwidth 20 MHz
Resolution 14 bits
Maximum Sampling Rate 100 MS/s
Memory Capacity 256 MB

Distribution Cache Shipping Info and Options

Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.

Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.

Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.

 

Shipping Options:

Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.

Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.

Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.

2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go

Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.

 

Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.

Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.

Question:

What are the key features of the National Instruments PXI-5412 Waveform Generator?

Answer:

The National Instruments PXI-5412 Waveform Generator has a maximum bandwidth of 20 MHz, 14-bit resolution, a sample rate of 100 MS/s, and 1 channel with 256 MB memory for the model 779176-03. It uses digital interpolation and analog filtering for improved passband flatness and image rejection, leading to a low-distortion output signal.

Question:

What are the different memory configurations available for the PXI-5412?

Answer:

The PXI-5412 is available in three memory configurations: 8 MB (Part Number: 779176-01), 32 MB (Part Number: 779176-02), and 256 MB (Part Number: 779176-03).

Question:

What software is required to operate the PXI-5412 Waveform Generator?

Answer:

The NI-FGEN driver software is required to operate the PXI-5412 Waveform Generator. It is compatible with software packages and application development environments like LabVIEW, LabWindows/CVI, or Measurement Studio.

Question:

What are the recommended calibration and warm-up practices for the PXI-5412?

Answer:

The recommended warm-up time for the PXI-5412 is 15 minutes, and it should be externally calibrated at least once every 2 years to ensure accuracy. Apex Waves can provide NIST accredited calibrations through a 3rd party or basic in-house calibrations to manufacturer specifications.

Question:

What is the status of the PXI-5412 and how can it be serviced?

Answer:

The PXI-5412 has been announced to have a Mature Status by National Instruments, but it is still available for purchase and repairs through Apex Waves. It can also be calibrated, with a variety of options offered by Apex Waves.