779793-01

National Instruments

779793-01

National Instruments

Description

The 779793-01 NI USB-8473s is a high-speed, USB CAN interface device designed for precise synchronization in automotive applications, featuring the Philips SJA1000 CAN controller and TJA1041 CAN handset. With the ability to timestamp messages in microseconds and optional hardware synchronization, it offers a versatile and reliable solution for creating applications with the NI-CAN controller.

779793-01 NI USB-8473s,1 Port High-Speed, USB CAN Interface/Synchronization National Instruments USB-8473 CAN Interface Device is a controller area network (CAN) interface designed for creating applications with the NI-CAN controller. This model features the Philips SJA1000 CAN controller and the TJA1041 CAN handset, offering features such as listen-only mode, rest/wakeup mode, access to the error counter, and auto-retransmit mode. With the ability to timestamp messages in microseconds, users can accurately record network events. The device operates at a maximum transfer rate of 1,000 kbit per second and is ideal for automotive applications requiring precise synchronization of CAN, LIN, analog, and digital measurements. With optional hardware synchronization, users can achieve true hardware synchronization between multiple USB-8473 interfaces and other devices for deterministic timing and triggering. The NI USB-8473 supports NI-CAN driver software and is compatible with software packages like LabVIEW. It features a voltage range of 12V to 16V, continuous and peak currents of 0.6A and 12A respectively, and a maximum power requirement of 20W. The CAN physical layer interfaces the CAN controller to transport wires, with options for fast and low-speed/fault-tolerant physical layers. The device includes onboard physical layer transceivers and requires no additional cables, with internally powered physical layers. Operating within a temperature range of -40 to 120 degrees Celsius, the NI USB-8473 is a versatile and reliable solution for advanced CAN applications.

Made By National Instruments
Part Number 779793-01
Interface Type USB CAN
Maximum Transfer Rate 1,000 kbit per second
Voltage Range 12 V to 16 V
Operating Temperature Range -40 to 120 degree Celsius

Distribution Cache Shipping Info and Options

Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.

Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.

Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.

 

Shipping Options:

Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.

Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.

Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.

2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go

Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.

 

Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.

Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.

Question:

What model of National Instruments USB CAN Interface is described in the text?

Answer:

The model described in the text is the 779793-01 NI USB-8473s.

Question:

Which CAN controller and CAN handset does the NI USB-8473 feature?

Answer:

The NI USB-8473 features the Philips SJA1000 CAN controller and the TJA1041 CAN handset.

Question:

What are some of the features supported by the NI USB-8473 device?

Answer:

Some of the features supported by the NI USB-8473 include listen-only mode, rest/wakeup mode, access to the error counter, and auto-retransmit mode.

Question:

What is the maximum transfer rate of the NI USB-8473, and what applications is it ideal for?

Answer:

The maximum transfer rate of the NI USB-8473 is 1,000 kbit per second, and it is ideal for automotive applications requiring precise synchronization of CAN, LIN, analog, and digital measurements.

Question:

What is the temperature operating range of the NI USB-8473, and what does it indicate about the device?

Answer:

The operating temperature range of the NI USB-8473 is -40 to 120 degrees Celsius, indicating that the device is versatile and reliable for advanced CAN applications, even in extreme conditions.