DAQCard-6062E
National Instruments
DAQCard-6062E
National Instruments
Description
The DAQCard-6062E from National Instruments is a high-quality data acquisition device designed for efficient and accurate data collection. With a unique part number and compatibility with various operating systems and software applications, this device offers versatility and reliability for professionals in the field.
The DAQCard-6062E is a high-quality data acquisition device manufactured by National Instruments. This model is specifically designed to provide efficient and accurate data collection for various applications. The device is equipped with several features and specifications that make it a reliable choice for professionals in the field. One of the notable specifications of the DAQCard-6062E is its part number, which is 777976-01. This unique identifier helps in distinguishing the specific model and ensures compatibility when purchasing or troubleshooting. In terms of compatibility, the device is designed to seamlessly work with various operating systems, including Windows NT, 2000, and XP. This ensures that users can connect and operate the card with ease on their preferred system without any compatibility issues. Furthermore, the DAQCard-6062E is highly compatible with multiple software applications. It can be integrated with popular programming languages such as LabVIEW, VI-Logger, Measurement Studio, C, C++, and Visual Basic. This broad compatibility enables users to leverage their programming skills and seamlessly integrate the card into their existing systems and workflows. When it comes to analog input channels, the DAQCard-6062E offers versatility. It can support either 8 differential or 16 single-ended input channels. This flexibility allows users to choose the appropriate channel configuration based on the specific requirements of their data acquisition tasks. Whether they need precise measurements from a few differential channels or a broader range of measurements from single-ended channels, the card delivers on both fronts. Overall, the DAQCard-6062E from National Instruments is a reliable and efficient data acquisition device. Its compatibility with different operating systems and software applications, along with its versatile analog input channels, make it a valuable tool for professionals seeking accurate and reliable data collection.
Made By | National Instruments |
---|---|
Model Number | DAQCard-6062E |
Part Number | 777976-01 |
Operating Systems | Windows NT/2000/XP |
Compatibility | LabVIEW, VI-Logger, Measurement Studio, C, C++, Visual Basic |
Analog Input Channels | 8 differential or 16 single-ended |
Distribution Cache Shipping Info and Options
Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.
Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.
Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.
Shipping Options:
Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.
Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.
Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.
2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go
Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.
Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.
Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.
Question:
What is the part number for the DAQCard-6062E?
Answer:
The part number for the DAQCard-6062E is 777976-01.
Question:
Which operating systems is the DAQCard-6062E compatible with?
Answer:
The DAQCard-6062E is compatible with Windows NT, 2000, and XP operating systems.
Question:
What programming languages can be used with the DAQCard-6062E?
Answer:
The DAQCard-6062E can be integrated with popular programming languages such as LabVIEW, VI-Logger, Measurement Studio, C, C++, and Visual Basic.
Question:
How many analog input channels does the DAQCard-6062E support, and what configurations are available?
Answer:
The DAQCard-6062E supports either 8 differential or 16 single-ended input channels, offering flexibility in channel configuration.
Question:
Why is the DAQCard-6062E considered a reliable choice for professionals?
Answer:
The DAQCard-6062E is considered a reliable choice for professionals due to its compatibility with various operating systems and software applications, and its versatility in offering different analog input channel configurations for accurate data collection.