Description

153639B-02L is a NI TB-2642B Terminal Block for National Instruments 2532B, designed for a 16 X 32 matrix. This switching accessory allows configuration of PXIe-2532B or PXI-2532B Switch Modules in a single-wire topology, with optional protection resistance available to prolong relay life.

153639B-02L is a NI TB-2642B Terminal Block for National Instruments 2532B, specifically designed for use as a 16 X 32 matrix. This switching accessory from National Instruments allows you to configure your PXIe-2532B or PXI-2532B Switch Module in a single-wire topology. The NI TB-2642B can be operated with optional protection resistance, which can help prolong the life of the Switch Module's reed relays and prevent degradation from capacitive loads. To order a unit with built-in protection resistance, use part number 782385-06, while the base version without protection resistance can be acquired through part number 782385-07. The NI TB-2642B features a row protection bypass header for bypassing the row protection resistors, and allows a maximum current flow of 0.4 amperes per channel. With a DC path resistance of less than 2.1 ohms, this Terminal Block is a reliable and efficient solution for your switching needs.

Made By National Instruments
Part Number 153639B-02L
Compatible Devices NI PXIe-2532B, PXI-2532B
Topology 16 x 32 Matrix
Current Capability 0.4 amperes (max per channel)
DC Path Resistance < 2.1 ohms

Distribution Cache Shipping Info and Options

Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.

Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.

Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.

 

Shipping Options:

Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.

Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.

Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.

2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go

Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.

 

Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.

Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.

Question:

What is the purpose of the NI TB-2642B Terminal Block?

Answer:

The NI TB-2642B Terminal Block is designed for use as a 16 X 32 matrix, allowing configuration of the National Instruments 2532B Switch Module in a single-wire topology.

Question:

What is the benefit of using optional protection resistance with the NI TB-2642B?

Answer:

Optional protection resistance with the NI TB-2642B can help prolong the life of the Switch Module's reed relays and prevent degradation from capacitive loads.

Question:

How can one order the NI TB-2642B with built-in protection resistance?

Answer:

To order the NI TB-2642B with built-in protection resistance, use part number 782385-06.

Question:

What does the row protection bypass header on the NI TB-2642B do?

Answer:

The row protection bypass header on the NI TB-2642B allows for bypassing the row protection resistors.

Question:

What is the maximum current flow and DC path resistance of the NI TB-2642B?

Answer:

The NI TB-2642B allows a maximum current flow of 0.4 amperes per channel and has a DC path resistance of less than 2.1 ohms.