SCC-A10

National Instruments

SCC-A10

National Instruments

SCC-A10 Image 1

Description

The SCC-A10 is a voltage attenuation module manufactured by National Instruments with a part number of 777459-06. It has a voltage attenuation factor of 10, an input voltage range of up to 60 VDC, and is suitable for a wide range of applications requiring accurate voltage measurements. It features two differential instrumentation buffer input channels, complies with safety specifications, and offers versatile connectivity options.

The SCC-A10 is a voltage attenuation module manufactured by National Instruments. It has a part number of 777459-06. This module has a voltage attenuation factor of 10, allowing it to reduce electrical signals by a factor of 10. The input voltage range supported by the SCC-A10 is up to 60 VDC. It has an input impedance of 1 mega ohm, ensuring minimal impact on the circuit being measured. With a bandwidth of 10 kHz, this module is suitable for a wide range of applications requiring accurate voltage measurements. It offers a minimum common-mode rejection ratio of 60 dB, ensuring that common-mode noise is effectively rejected for accurate measurements. The analog power requirement is a maximum of 100 mW, with a maximum current draw of 3.2 mA at +15 V and -15 V. The SCC-A10 does not require any digital power for operation, making it a low-power module. It is designed to operate in a temperature range of 0 to 50 degrees Celsius. For storage purposes, it can endure temperatures ranging from -20 to 70 degrees Celsius. This voltage attenuation module complies with safety specifications including IEC 61010-1 and EN 61010-1, ensuring reliable and safe operation. It is compatible with NI-DAQmx software, enabling seamless integration and control within NI's data acquisition ecosystem. In terms of physical attributes, the SCC-A10 has dimensions of 3.55 x 7.93 x 1.87 cm (width x length x depth) and weighs 29 grams. It features two differential instrumentation buffer input channels for capturing measurement data. It comes with connectors including one 20-pin right-angle male connector and one 4-pin screw terminal I/O connector, offering versatile connectivity options.

Made By National Instruments
Model Number SCC-A10
Part Number 777459-06
Voltage Attenuation Factor 10
Input Voltage Range 60 VDC
Input Impedance 1 mega ohm

Distribution Cache Shipping Info and Options

Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.

Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.

Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.

 

Shipping Options:

Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.

Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.

Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.

2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go

Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.

 

Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.

Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.

Question:

What is the purpose of the SCC-A10?

Answer:

The SCC-A10 is a voltage attenuation module designed to reduce electrical signals by a factor of 10.

Question:

What is the maximum input voltage that the SCC-A10 can handle?

Answer:

The SCC-A10 can handle an input voltage range of up to 60 VDC.

Question:

What is the bandwidth of the SCC-A10 and why is it significant?

Answer:

The SCC-A10 has a bandwidth of 10 kHz, making it suitable for a wide range of applications that require accurate voltage measurements.

Question:

What are the environmental temperature ranges for the operation and storage of the SCC-A10?

Answer:

The SCC-A10 can operate in a temperature range of 0 to 50 degrees Celsius and can be stored in temperatures ranging from -20 to 70 degrees Celsius.

Question:

What makes the SCC-A10 compatible with NI's data acquisition ecosystem?

Answer:

The SCC-A10 is compatible with NI-DAQmx software, which enables seamless integration and control within National Instruments' data acquisition ecosystem.