SCC-TC02

National Instruments

SCC-TC02

National Instruments

SCC-TC02 Image 1

Description

The SCC-TC02 is a versatile thermocouple module by National Instruments, supporting multiple thermocouple types and featuring a gain of 100 differential amplifiers, a dual-pole 2 Hz filter, and bias and pull-up resistors for accurate temperature measurements. Its part number, 777459-04, is essential for identifying and ordering the correct module.

The SCC-TC02 is a thermocouple module manufactured by National Instruments. It is designed for measuring temperature using various thermocouple types. The specific model number for this module is SCC-TC02. One of the key specifications of this module is its part number, which is 777459-04. This part number is essential for identifying and ordering the correct module. The SCC-TC02 supports a wide range of thermocouple types, including B, E, J, K, N, R, S, and T. This means that it can be used with thermocouples that use any of these types, allowing for versatile temperature measurements. The module has a single input channel dedicated to a thermocouple. It is equipped with a gain of 100 differential amplifiers, which enhances the accuracy and stability of the temperature measurements. Additionally, this module includes a dual-pole 2 Hz filter, which helps eliminate unwanted noise and interference from the measurements. To ensure the accuracy of temperature readings, the SCC-TC02 includes a bias resistor. This resistor has a value of 10 M? and is used in conjunction with a 10 M? pull-up resistor. These resistors work together to provide the necessary electrical conditions for accurate temperature measurements. In summary, the SCC-TC02 is a thermocouple module manufactured by National Instruments. It supports multiple thermocouple types and includes various features such as a gain of 100 differential amplifiers, a dual-pole 2 Hz filter, and bias and pull-up resistors to ensure accurate temperature measurements.

Made By National Instruments
Model Number SCC-TC02
Part Number 777459-04
Supported Thermocouple Types B, E, J, K, N, R, S, T
Input Channel One thermocouple input channel with gain of 100 differential amplifiers and a dual-pole 2 Hz filter
Bias Resistor 10 Mω bias resistor with 10 Mω pull-up resistor

Distribution Cache Shipping Info and Options

Shipping Carriers: Here at Distribution Cache we ship using UPS, FedEx, DHL, or TNT. In most cases we get very competitive rates based on our volume and will be happy quote shipping cost to your location upon request. We also know that many customers would prefer to ship collect on their own account numbers and welcome this option.

Shipping Blind: We recognize that many of our customers intend to re-sell the product to their end user. We respect our customer’s relationships with their clients and offer blind shipping as an option to ensure that the package arrives in the most clandestine way possible.

Shipping Process: We take pride in the way we package your order and spare no cost in making sure that it arrives safely at your facility. In the case of new parts, we are always sure to package the factory box inside another larger box for safe transit. For reconditioned parts we often use Distribution Cache customized packaging that is specially made to protect the products from the bumps and falls present during shipment.

 

Shipping Options:

Next Day Air Early AM - This service is the fastest overnight delivery option available. For most locations the package will be guaranteed by 8:30AM.

Next Day Air – This service guarantees delivery by 10:30AM and is the most frequently used option for overnight shipments.

Next Day Air Saver – This cost saving overnight alternative guarantees delivery by 3PM the next day.

2nd Day Air – For domestic shipments that would take 3-5 days if shipped via Ground, sometimes having the order in 2 days is a great way to go

Ground – Ground is the most inexpensive shipping option provided. Please ask if we are doing a “free domestic ground” shipping promotion on your order. We often provide free ground shipping on larger orders.

 

Emergency Courier – At times we can help work with a courier service to get the part to your facility during downtimes scenarios. We prefer that the customer sets up the courier but we can be there to make sure the product is handed off to the driver. Please give us a call to see if this is an option on your order.

Please Note: Products listed as “ships today” can ship same-day if an order is placed before 4PM. For larger drives and motors we ask that notification for same-day shipments be provided by 2PM at the latest. For any products listed as “ships in 3-5 days”, please give us a call to see if this can be expedited.

Question:

What is the SCC-TC02 and who manufactures it?

Answer:

The SCC-TC02 is a thermocouple module manufactured by National Instruments.

Question:

What is the focal use of the SCC-TC02 module?

Answer:

The SCC-TC02 module is designed for measuring temperature using various thermocouple types.

Question:

What is the part number for the SCC-TC02 module?

Answer:

The part number for the SCC-TC02 module is 777459-04.

Question:

What thermocouple types does the SCC-TC02 support?

Answer:

The SCC-TC02 supports a wide range of thermocouple types, including B, E, J, K, N, R, S, and T.

Question:

What features does the SCC-TC02 include to ensure accurate temperature measurements?

Answer:

The SCC-TC02 includes a gain of 100 differential amplifiers, a dual-pole 2 Hz filter, and bias and pull-up resistors valued at 10 M? each to ensure accurate temperature measurements.